 Sensing element/Gauge
Features
. Dual-In-line-Package(DIP)or Horizontal pressure port, Easy to mount on PCB . Vacuum pressure measurable . Non-corrosive liquid measurable(FPMC/FHMC available)
FPM,FHM Data sheet
Applications
. Industrial instrumentation . Pressure switch, Pneumatic device . Medical device . Turbo boost pressure measurement for Automotive system
Part number for ordering
FPM C - 07P G R
Model FPM FHM Rated pressure (PSI) Terminal leads direction(See Outline Diagram) No mark :
R: Pressure type Available pressure media G : Gauge pressure No mark : Non-corrosive gas only C : Non-corrosive gas and liquid(Contact us about availability)
Gauge pressure FPM FHM
Pressure type
Model
Package configuration Measurable pressure range(kPa) 13.79 13.79 34.47 34.47 48.26 48.26 98.07 103.4 98.07 206.8 98.07 344.7 98.07 482.6 98.07 827.4
Dual-In-line-Package(DIP)
Horizontal pressure port DIP
FPM-02PG FPM-05PG FPM-07PG FPM-15PG FPM-30PG FPM-50PG FPM-70PG FPM-120PG
Part number for ordering FPM-02PGR FHM-02PG FPM-05PGR FHM-05PG FPM-07PGR FHM-07PG FPM-15PGR FHM-15PG FPM-30PGR FHM-30PG FPM-50PGR FHM-50PG FPM-70PGR FHM-70PG FPM-120PGR FHM-120PG
FHM-02PGR FHM-05PGR FHM-07PGR FHM-15PGR FHM-30PGR FHM-50PGR FHM-70PGR FHM-120PGR
Specifications
Model/Rated pressure 02PG 05PG 07PG 15PG 30PG 50PG 70PG 120PG unit
Recommended operating conditions Pressure type Gauge pressure 13.79 34.47 48.26 103.4 206.8 344.7 482.6 Rated pressure 0.141 0.352 0.492 1.055 2.109 3.516 4.922 13.79 34.47 48.26 98.07 98.07 98.07 98.07 Measurable pressure range 13.79 34.47 48.26 103.4 206.8 344.7 482.6 Pressure media FPM, FHM : Non-corrosive gas only, FPMC, FHMC : Non-corrosive gas and liquid Excitation current(Constant) 1.5 Absolute maximum rating Maximum load pressure Twice of rated pressure Maximum excitation current 3 Operating temperature 20 100 Storage temperature 40 120 Operating humidity 30 80(No dew condensation) Electric performances/characteristics(Excitation current I=1.5mA constant, Ambient temperature Ta=25 ) Full scale span voltage 60 140 Offset voltage 20 Bridge impedance 4000 6000 Mechanical response time 2(For the reference) Temperature sensitivity of offset(TSO) 5 Temperature coefficient of sensitivity(TCS) 2.5 Linearity 0.5 0.3 0.5 Pressure hystersis 0.4 0.2 Accuracy
Please consult us available liquid pressure media when you choose the C models.
827.4 8.437 98.07 827.4
kPa kg/cm2 kPa
mADC 1.5times of rated pressure mADC
RH mV mV msec FS/0 50 FS/0 50 FS FS
0.6 0.4
1
Sensing element/Gauge
Outline dimensions
FPM,FHM Data sheet
unit(mm)
FPM
12 6 5 4 4 2.2 8
5 0.2
max 15
Pressure port 0.8 0.6 Vent hole
4.5 4 5 6
15.24(600mil)
R1.5 3 C0.5
14
1
2
3 Terminal leads
3
2
1
Labelled faceplate
6.8 2.8
Recommended footprint for PCB
6- 0.9(Diameter of through holes)
2.54 2.54
6- 1.8(Diameter of lands)
1.2
60
15.2
unit(mm)
unit(mm)
FPM-R
0.2
12
max 15
4 2.2
8
5
6
5
4
0.8 Pressure port
4
5
6
R1.5 14 3
C0.5 1 2 3 Terminal leads Labelled faceplate 0.6 Vent hole 32 4.5 1
15.24(600mil)
0.5
2.54 2.54
Recommended footprint for PCB
6- 0.9(Diameter of through holes) 6- 1.8(Diameter of lands)
1.2
60
2.8 6.8
15.2
unit(mm)
2
2.54 2.54
2.54 2.54
0.5
Sensing element/Gauge
Outline dimensions
FPM,FHM Data sheet
FHM
2.54 2.54 1 2 3
unit(mm)
Pressure port 6 (14) 5 4
15
0.25 1
3.2
0.6
5.5 2.6 6 10.15 Vent hole 8 Labelled faceplate 6 5 4 1.2 3.4 7.6
Recommended footprint for PCB
6- 1(Diameter of through holes) 6- 1.8(Diameter of lands)
8
1
2
3
10
FHM-R
1
2.54 2.54 2 3
unit(mm)
Pressure port
6
5
4
(14) 1.2
1
3.2
1.55
5.5
2.6
6
15
10.16
0.25
Vent hole 0.6 Labelled faceplate 8 6 5 4
4.7
3.4 (7.6)
Recommended footprint for PCB
6- 1(Diameter of through holes) 6- 1.8(Diameter of lands)
8
1
2
3
10
3
2.54 2.54
1
2.54 2.54
unit(mm)
unit(mm)
Sensing element/Gauge
Connection diagram
FPM,FHM Data sheet
unit(mm)
FPM, FHM
i
1.5mA
2 Output voltage R2 Constant current source 3 6 R3 R4 1 6 Zero balancing trimmer (VR0) is available. VR0 :200 R1 1
5
VR0
Note ; Please read instruction "Notes" before using the sensor. Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 4 E-mail : sensor@fujikura.co.jp


▲Up To Search▲   

 
Price & Availability of FPMC-07PGR

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X